Charing Cross Hospital, 1.5T MRI Suite Refurbishment

Mechanical services for the refurbishment of the North Wing Radiology 1.5T MRI suite for Imperial College Healthcare NHS Trust.

£350kHealthcareImperial College Healthcare NHS TrustNew AHUs
Charing Cross Hospital, Fulham Palace Road

Overview

We completed the mechanical services installation associated with the refurbishment of the North Wing Radiology Department 1.5T MRI suite at Charing Cross Hospital for Imperial College Healthcare NHS Trust. The project involved a complete refurbishment of the MRI treatment room, technical equipment room and associated ancillary areas within a live hospital environment, where maintaining continuity of existing services was critical.

Scope of works

Our scope included the removal of redundant mechanical plant, ductwork, pipework, controls, supports and associated equipment, followed by the installation of the new mechanical services infrastructure.

The completed works incorporated new supply and return air handling units, ventilation distribution ductwork, silencers, dampers and thermal insulation, together with LTHW heating and chilled water systems serving the AHU coils.

Additional works included domestic mains cold water services, trace heating, MRI examination room ventilation, wave guides, emergency helium evacuation, medical gas adaptations and specialist cooling installations serving the MRI technical room.

Outcome

The installation also incorporated MCC and BMS controls, associated power and control wiring, sensors and containment. All mechanical systems were tested, commissioned and integrated to provide a complete operational installation supporting the refurbished MRI facility.

Project photographs

Charing Cross Hospital, Fulham Palace Road
Charing Cross Hospital, Fulham Palace Road

Planning a similar project?

Send us your drawings and specification, or call the office to discuss the programme.

Get in touch with Preou HVAC Ltd

Tell us about the building and the plant, and a member of the team will come back to you to discuss the project in detail.

TelephoneCall us
Email 
Office8 Radford Crescent, Billericay, Essex CM12 0DU

Key contacts

  • Daniel Herold, Managing Director
  • Julia Herold, Finance Director
  • Charles Romero, Business Development

Start a project

Send drawings, a specification or a description of the plant. We reply within one working day.

We reply within one working day.